ABR & OAE

Neuro-Audio

Yeni doğan, çocuk ve yetişkinlerin odiometri ABR ve OAE için Dijital Sistem 

2-channel ABR, OAE, VEMP, ASSR and ECochG System

Main Features:

  • all-in-one solution for auditory EP and OAE acquisition
  • automatic multi-ASSR test
  • high acquisition quality
  • VEMP with biofeedback
  • new standard for routine tests
  • Auditory brainstem response (ABR) / Brainstem evoked response audiometry (BERA)
  • Transient evoked otoacoustic emission (TEOAE)
  • Distortion product otoacoustic emission (DPOAE)
  • Middle- and long-latency auditory evoked potentials (AEP: MLR, LLR)
  • Vestibular evoked myogenic potentials (VEMP)
  • Auditory steady-state response (ASSR)
  • Electrocochleography (ECochG)
  • Cognitive evoked potentials (MMN, P300)

 Neuro-Audio-2010-1

 

Neuro-Audio (version 2010) view

 

Neuro-Audio-2010-2

 

Some of supported transducers

 

Neuro-Audio-2010-3

 

Simple and fast workflow

 

Neuro-Audio-2010-4

 

EABR test

 

Neuro-Audio-2010-5

 

DPOAE test

One Device for All Audiological Tests

Most of the tests needed for your daily audiological practice are in just one box with the size of a small book, powered from a personal computer. This Neuro-Audio (version 2010) device has:

  • One USB cable to connect device to a computer
  • Set of sockets on side bottom panel to connect all stimulators: headphones, insert earphones, OAE probe and bone vibrator
  • 5 touch-proof connectors to plug electrodes
  • 2 DIN connectors
  • LED impedance indicator and “Impedance check” button
  • Combined trig-in and trig-out socket (to connect to DIB for cochlear implant, for example)

No other devices, cables, batteries, chargers and power supply units needed!

Many Supported Transducers

Neuro-Audio (version 2010) supports many transducers for audiometric tests available on the market.

The software specifies ipsi- and contra-lateral curves in multi-channel recording.

Simple and Fast Workflow

Neuro-Audio.NET software provides a simple workflow to perform tests.

Step 1. Enter patient‘s information to the database
Step 2. Select from the list what test you want to do
Step 3. Press "Run" button and test is performed automatically
Step 4. Once a test is done, software tries to arrange the markers automatically, however, you can correct them manually. Immediately you see all related graphs and tables. If reference values are set for this test, you see all figures compared with reference numbers
Step 5. Press "Report" button and report is generated in editable format (Microsoft Word)

Unlimited Flexibility

When the software is installed, all tests are preset for daily practice. And you do not need to make any changes. But when you need it, you can change practically any parameter you wish: parameters of acquisition and stimulation, window layout, colors, report, etc.

Shortest ABR Acquisition Time

Neuro-Audio.NET has several signal processing features which significantly decrease ABR acquisition time:

  1. Weighted averaging decreases required quantity of sweeps to get a clear trace
  2. “Minimize interference” feature helps to reduce electrical interference
  3. Chirp stimulus activates all cochlear hair cells simultaneously which increases signal amplitude
  4. High frequency stimulation. Even at 50 Hz stimulation you still clearly see peak V. But this decreases test duration by up to 5 times comparing with 11 Hz stimulation
  5. Statistical algorithms for online objective analysis of waveforms for response presence (Fsp/Fmp) eliminate observer‘s subjectivity and save valuable test time

Fast ABR Analysis

  1. Automatic ABR marker arrangement with possibility of manual correction A/B buffers to check reproducibility quickly
  2. Automatically displayed normative data (reference values) based on patient’s age
  3. Latency/intensity graphs and analysis tables
  4. 64-bit data processing on 64-bit computers

Automatic ABR Threshold Search Protocol

ABR threshold search is one of the most widespread routine tests in objective audiometry. We developed a special automatic ABR protocol “Objective hearing threshold search”. In this mode the whole process is done automatically. You need only to prepare a patient, start this protocol and simply observe the procedure, stopping it when you see the threshold.

New and Traditional ABR

  • Traditional click ABR
  • Tone burst ABR to estimate frequency-specific hearing thresholds
  • Bone conduction ABR for infants with ear canal atresia or other structural malformations
  • Chirp ABR (wideband, frequency-specific)
  • Electric ABR (EABR) for patients with cochlear implants

Screening Mode for OAE

DPOAE and TEOAE tests can be performed in screening mode. In this mode minimum interaction with the machine is needed to perform the test. Software tells you what to do next or does it automatically. The results appear as a simple phrase “PASS” or “REFER”. Technician can be easily trained to perform screening tests.

12-point DPOAE mode is available (with frequencies up to 12 kHz).

Multi-ASSR: State of the Art Implementation

  • Minimization of test duration: stimulation of both ears simultaneously using 4 carrier frequencies (500 Hz, 1 kHz, 2 kHz and 4 kHz) in each ear.
  • Independent intensity control for each of 8 stimuli.
  • Effective stimulus enhancing the response amplitude (exponential modulation, narrow-band chirp)
  • Accurate objective technique of response detection (F-test)
  • Two-channel recording improves the signal-to-noise ratio and reduces test time
  • The same electrode placement as in ABR can be used
  • Automatic conversion of frequency-specific ASSR thresholds to estimated audiogram
  • Weighted averaging (with improved accuracy, reduced test time)
  • Independence from patient’s state (2 modulation modes: awake (40 Hz) and asleep (90 Hz))
  • Modulation mode can be changed during test (if awake patient fell asleep, for example)
  • Monitoring of response amplitude and noise floor per ear and per frequency
  • All ASSR data are displayed on a single screen (including response probability and spectrum)

Pure Tone Audiometry with up to 16 kHz Stimulation

Pure tone audiometry test with air and bone conduction can be performed with the same device and in the same software, with the same interface which is used for objective test. You do not need to register or recall your patient when you go to PTA test. You just press “New test” button.

Test can be performed automatically (Hughson-Westlake algorithm), or you can control it manually using hot keys on PC keyboard. Patient responds to the stimulus using a remote button.

High-frequency audiometry is supported (up to 16 kHz) with these transducers: HDA-200 and ER-2.

VEMP with Biofeedback

  • cVEMP (cervical) and oVEMP (ocular) test templates
  • EMG-controlled recording
  • Biofeedback: patient’s monitor to observe muscle tension
  • Automatic calculation of VEMP ratio (right-left asymmetry)

And More

  • Traditional single-frequency ASSR
  • MLR, LLR: middle and long-latency evoked potentials
  • You can use calibrated loudspeakers to perform tests in a free sound field
  • MMN and P300 for cognitive function evaluation
  • ECochG: electrocochleography test

At the Cutting Edge of Science

Access to all amplifier, stimulator and signal processing settings allows you to create your own custom test templates, for all your scientific research needs. And if you feel you miss some flexibility or feature, you can always contact our powerful engineering team directly. We are open to innovations!

 
  • Neuro-Audio electronic unit
  • Holder
  • OAE probe
  • OAE probe tip
  • Test cavity
  • Set of ear tips (universal) (3-14 mm diameter, 165 pcs.)
  • Set of accessories for AEP acquisition
    • Cup electrode with cable— 5 pcs.
    • Y-adapter cord
    • Adapter for 2-channel EP recording
    • Cable for disposable electrode: “Alligator” clip - touch-proof (1 m) (green, blue, red or black)
    • Disposable surface electrode (100 pcs.)
  • Auditory stimulator for EP (TDH-39 acoustically shielded headphones)
  • Electrode adhesive paste Ten20 (114 g)
  • Abrasive paste for skin preparation (160 g)
  • Medical tape
  • Dental floss for probe tip cleaning
  • Probe tip extractor
  • Neuro-Audio.NET software with ABR, MLR, LLR and OAE modules
  • Technical manual
  • User manual

avmlogo

AVM Sağlık Sistemleri ürün ve hizmetleri konusunda ilgileniyor ve yeniliklerden haberdar olmak istiyorsanız; bizi takip edin...

encoksatan logo

orjinal-urun

İletişim

AVM Sağlık Hizmetleri Ltd. Şti.

Küçükbakkalköy Mh. Gül Ağacı Sk.
No:13 34750 Ataşehir - İstanbul

Tel: +90 (216) 368 18 00
Faks: +90 (216) 368 19 00

E-posta: bilgi@avmsaglik.com.tr